Migibio logo Migibio Request a Quote
Migi (Dog) Canine N-Terminal Pro-Brain Natriuretic Peptide (cNT-proBNP) Rapid Quantitative Test Kit

Migi (Dog) Canine N-Terminal Pro-Brain Natriuretic Peptide (cNT-proBNP) Rapid Quantitative Test Kit

Catalog No.: MG-CA-R019

Migi (Dog) Canine N-Terminal Pro-Brain Natriuretic Peptide (cNT-proBNP) Rapid Quantitative Test Kit — a quantitative fluorescence immunochromatography (FICT) rapid test for canine diagnostics, delivering results in minutes with pg/ml-level sensitivity. CE/ISO9001-compliant manufacturer. Cat. No. MG-CA-R019.

Catalog Number: MG-CA-R019

Product Specifications

AttributeValue
Place of OriginChina
ClassificationSpecific Reagents
CAT No.MG-CA-R019
PackageBox
AppearanceLiquid
Specification10T
StorageRoom Temperature
Shelf life2 years
MOQ10 boxes
Suitable forVeterinary
GradeReagent Grade

Specification

Package Size : 10 Tests/Box Catalog Number : MG-CA-R019

Intended Use

The cNT-proBNP test is a fluorescence immunoassay designed for the quantitative determination of N-terminal pro-brain natriuretic peptide (cNT-proBNP) concentration in canine serum or plasma. It aids in evaluating the risk of cardiac failure in dogs. For in vitro diagnostic use only . Professional use only.

Clinical Significance

Canine N-terminal pro-B-type natriuretic peptide (cNT-proBNP) is a sensitive marker of cardiac wall stress and volume overload, released in response to myocardial stretch. It is used to differentiate cardiac from respiratory causes of clinical signs such as cough and dyspnoea.

Quantitative cNT-proBNP measurement supports the early detection of congestive heart failure and myxomatous mitral valve disease (MMVD), and assists in monitoring response to cardiac therapy.

Test Principle

This test employs a quantitative double-antibody sandwich fluorescence immunoassay technique. The fluorescent signal intensity correlates with the amount of cNT-proBNP captured. Results are expressed in pmol/L.

Materials Provided

Contents Quantity Individual Sealed Pouches 10

    • Test Device Per pouch
    • Desiccant Pouch Per pouch ID Chip 1 Instructions for Use 1 cNT-proBNP Sample Buffer Tubes 10 Pipette Tips 10 Materials Required but Not Provided: Immunofluorescence Analyzer Timer Pipette Centrifuge

Storage and Stability

Store the test kit at 4–30℃ until the expiration date. Perform the test at 18–28℃ after opening the pouch. Once the pouch is opened, the test should be used within 30 minutes .

Specimen Collection and Preparation

This test can be performed using serum or plasma (EDTA anticoagulant recommended). Separate serum or plasma from blood within 3 hours of collection. If hemolysis is severe, obtain a new specimen. Perform the test immediately after specimen collection. If testing is delayed, store the specimen at 2–8℃ for no longer than 72 hours or below -20℃ for long-term storage. Before testing, bring all materials to room temperature. Ensure that frozen specimens are fully thawed and mixed well. Avoid repeated freezing and thawing. Only clear, non-hemolyzed specimens should be used.

Test Procedure

Refer to the Immunofluorescence Analyzer Operation Manual for detailed instructions. Place the Test Device on a clean, level surface. Insert the ID Chip into the analyzer and click “Read ID Chip.” Ensure the Test Device lot number matches the ID Chip number. Pipette 50 μl of the prepared sample into the cNT-proBNP Sample Buffer and mix gently. Transfer 100 μl of the mixed sample to the sample well (S) on the Test Device. Avoid forming bubbles. Select the Test Mode: Standard Test : Insert the Test Device into the analyzer immediately, select “Serum/Plasma,” and start the test. The results will be displayed automatically. Quick Test : Let the Test Device sit at room temperature for 10 minutes , then insert it into the analyzer, select “Serum/Plasma,” and start the test. Results will be displayed automatically. Results will be displayed on the screen, printed automatically, or printed manually by selecting “Print.”

Quality Control

Each cNT-proBNP Rapid Quantitative Test includes an internal control for routine quality control. If an invalid result occurs, the analyzer will display an error message, indicating that the test should be repeated.

Interpretation of Results

Detection Range : 450 ~ 10,000 pmol/L Conversion Factor : 1 pmol/L = 8.457 pg/ml Reference Ranges : Result (pmol/L) Suggestion ≤ 900 Normal 900 – 1800 Suspected (SUS)

1800 Abnormal Each laboratory should establish its own reference range based on the population being tested.

Warnings and Limitations

For in vitro diagnostic use only . Inspect the packaging and labels before use. Do not use the product if the pouch is damaged or not properly sealed. Do not use the test device beyond the expiration date. Use one pipette tip per specimen. Technical or procedural errors, along with unlisted substances in blood specimens, may interfere with the test and result in erroneous outcomes.