Migibio logo Migibio Request a Quote
Migi (Dog) Canine Cortisol (cCortisol) Rapid Quantitative Test Kit

Migi (Dog) Canine Cortisol (cCortisol) Rapid Quantitative Test Kit

Catalog No.: MG-CA-R018

Migi (Dog) Canine Cortisol (cCortisol) Rapid Quantitative Test Kit — a quantitative fluorescence immunochromatography (FICT) rapid test for canine diagnostics, delivering results in minutes with pg/ml-level sensitivity. CE/ISO9001-compliant manufacturer. Cat. No. MG-CA-R018.

Catalog Number: MG-CA-R018

Product Specifications

AttributeValue
Place of OriginChina
ClassificationSpecific Reagents
CAT No.MG-CA-R018
PackageBox
AppearanceLiquid
Specification10T
StorageRoom Temperature
Shelf life2 years
MOQ10 boxes
Suitable forVeterinary
GradeReagent Grade

Specification

10 Tests/Box Cat. No.: MG-CA-R018

Intended Use

The cCortisol test is a fluorescence immunoassay designed for use with an Immunofluorescence Analyzer to quantitatively measure cCortisol levels in canine serum or plasma specimens. For in vitro diagnostic use only. Professional use only.

Clinical Significance

Canine cortisol measurement is central to the diagnosis of hyperadrenocorticism (Cushing’s syndrome) and hypoadrenocorticism (Addison’s disease), two significant endocrine disorders with widely differing presentations.

Quantitative cCortisol testing supports screening and monitoring of adrenal function, including ACTH stimulation and low-dose dexamethasone suppression testing protocols.

Test Principle

This test utilizes a quantitative competitive fluorescence immunoassay technique. The fluorescence intensity corresponds to the amount of cCortisol present, and the concentration is reported in μg/dL or nmol/L.

Materials Included

Individual Sealed Pouches (10) Test Device (1 per pouch) Desiccant Pouch (1 per pouch) ID Chip (1) Instructions for Use (1) cCortisol Sample Buffer Tubes (10) Pipette Tips (10) Materials Required but Not Provided: Immunofluorescence Analyzer Timer Pipette Centrifuge

Storage and Stability

Store the test kit between 4°C and 30°C until the expiration date. The test should be conducted between 18°C and 28°C once the pouch is opened. Perform the test within 30 minutes of opening the pouch.

Specimen Collection and Preparation

Suitable specimens: serum or plasma (EDTA anticoagulant recommended). Separate serum or plasma from blood within 3 hours of collection. If hemolysis occurs, collect a new specimen. Perform the test immediately after collection if possible. Otherwise, store the specimen at 2°C to 8°C for up to 72 hours, or below -20°C for long-term storage. Bring all materials to room temperature before testing. Thaw frozen specimens completely and mix thoroughly. Avoid repeated freeze-thaw cycles. Only clear, non-hemolyzed specimens should be used.

Test Procedure

Set the Test Device on a clean, level surface. Insert the ID Chip into the analyzer and ensure the Test Device lot number matches the ID Chip number. Pipette 50 μL of prepared sample into the cCortisol Sample Buffer tube and mix gently (avoid foaming). Pipette 100 μL of the mixed sample into the sample well (S) of the test device. Choose test mode: Standard Test : Insert the Test Device into the analyzer immediately and click “Start Test”. Select “Serum/Plasma”. The analyzer will automatically provide results. Quick Test : Start a timer after adding the sample to the Test Device. Allow the test to incubate at room temperature (18°C - 28°C) for 10 minutes, then insert the Test Device into the analyzer and click “Start Test”. Select “Serum/Plasma”. Results are displayed on the screen and can be printed automatically or manually.

Quality Control

Each cCortisol Rapid Quantitative Test includes an internal control to meet routine quality control standards. If the internal control fails, the analyzer will display an error message, indicating the need to repeat the test.

Interpretation of Results

Reference range for cCortisol in canine serum or plasma: ACTH Stimulation Test ACTH Before Use (nmol/L) Suggestion ACTH After Use (nmol/L) Suggestion < 55 Possible adrenal insufficiency < 55 Possible adrenal insufficiency 55 - 166 Normal 55 - 166 Suspected

166 High 166 - 498 Normal 498 - 663 Suspected 663 Hyperadrenocorticism

Lddst

4-Hour Cortisol (nmol/L) 8-Hour Cortisol (nmol/L) Suggestion

< 28 Normal 28 - 39 Suspected

39 & > 50% base value Hypofunction of adrenal cortex < 39 & < 50% base value 39 & > 50% base value PDH

Hddst

4-Hour Cortisol (nmol/L) 8-Hour Cortisol (nmol/L) Suggestion < 39 & < 50% base value

39 & > 50% base value PDH 39 & > 50% base value < 39 & < 50% base value PDH 39 & > 50% base value Further testing required Detection range: 28 ~ 1700 nmol/L Conversion factor: 1 nmol/L = 0.036 μg/dL Each laboratory should establish a reference range based on the population being evaluated.

Warnings and Limitations

For in vitro diagnostic use only. Inspect all packaging before use. Do not use the test if the packaging is damaged or the vial is leaking. Do not use expired test devices. Use a new pipette tip for each specimen. Technical or procedural errors, as well as interfering substances in the blood, may affect test results.