Migibio logo Migibio Request a Quote
Migi (Cat) Feline Panleukopenia Virus Antibody (FPV-Ab) Rapid Quantitative Test

Migi (Cat) Feline Panleukopenia Virus Antibody (FPV-Ab) Rapid Quantitative Test

Catalog No.: MG-CA-R011

Migi (Cat) Feline Panleukopenia Virus Antibody (FPV-Ab) Rapid Quantitative Test — a quantitative fluorescence immunochromatography (FICT) rapid test for feline diagnostics, delivering results in minutes with pg/ml-level sensitivity. CE/ISO9001-compliant manufacturer. Cat. No. MG-CA-R011.

Catalog Number: MG-CA-R011

Product Specifications

AttributeValue
Place of OriginChina
ClassificationSpecific Reagents
CAT No.MG-CA-R011
PackageBox
AppearanceLiquid
Specification10T
StorageRoom Temperature
Shelf life2 years
MOQ10 boxes
Suitable forVeterinary
GradeReagent Grade

Specification

10 Tests/Box Catalog No.:

Mg-Ca-R011

Intended Use

The FPV-Ab test is a fluorescence immunoassay intended for use with an Immunofluorescence Analyzer to quantitatively determine the concentration of panleukopenia virus antibodies (FPV-Ab) in serum or plasma. This test can be used to assess the level of FPV-Ab titer following pet vaccination, helping to determine whether a booster vaccination is necessary. Additionally, it aids in the diagnosis and monitoring of feline panleukopenia virus infection. For in vitro diagnostic use only. For professional use only.

Clinical Significance

Feline panleukopenia virus (FPV) is a highly contagious and often fatal parvovirus of cats. Vaccination is highly effective, and antibody titres are a reliable indicator of protective immunity.

Quantitative FPV antibody measurement allows clinicians to confirm vaccination efficacy, identify cats with inadequate protection, and tailor booster schedules — particularly important in shelters and breeding facilities.

Test Principle

The test uses a quantitative double antigen sandwich fluorescence immunoassay technique. The intensity of the fluorescent signal is proportional to the amount of FPV-Ab captured, and the concentration is expressed as Tu/ml.

Materials Provided

Contents Quantity Individual Sealed Pouches 10 – Test Device 1 per pouch – Desiccant Pouch 1 per pouch ID Chip 1 Instructions for Use 1 FPV-Ab Sample Buffer Tubes 10 Pipette Tips 10 Materials Required But Not Provided: Immunofluorescence Analyzer Timer Pipette Centrifuge

Storage and Stability

Store the test kit at 4–30°C until the expiration date. Operate the test between 18–28°C after opening the Test Device. Perform the test within 30 minutes after opening the pouch.

Specimen Collection and Preparation

The test is suitable for serum or plasma (EDTA anticoagulant recommended). Separate serum or plasma from blood within 3 hours of collection. Avoid using severely hemolyzed specimens; obtain a new sample if necessary. Perform the test immediately after specimen collection. If not possible, store the specimen at 2–8°C for up to 72 hours. For long-term storage, freeze specimens below -20°C. Bring all materials to room temperature before use. Thaw frozen specimens completely and mix well. Do not refreeze specimens after thawing. Only use clear, non-hemolyzed specimens.

Test Procedure

Refer to the Immunofluorescence Analyzer Operation Manual for detailed instructions. Place the Test Device on a clean, level surface. Insert the ID Chip into the meter, and select “Read ID chip” to ensure the Test Device lot number matches the ID Chip number. Pipette 20 μl of the prepared sample into the FPV-Ab Sample Buffer and mix gently, avoiding vigorous agitation and foaming. Add 100 μl of the mixed sample to the sample well (S) of the Test Device, ensuring no bubbles form. Test Mode Options: a) Standard Test: Select “Standard Test,” insert the Test Device into the meter holder immediately after adding the sample, and click “Start Test.” Choose the sample type “Serum/Plasma.” The meter will automatically read the result after counting down. b) Quick Test: Select “Quick Test,” start the timer immediately after adding the sample to the well, and leave the Test Device at room temperature (18–28°C) for 10 minutes. Insert the device into the meter holder and click “Start Test.” Select the sample type “Serum/Plasma.” The meter will scan the device and display the result. Results are displayed on the main screen, printed automatically, or by clicking “Print.”

Quality Control

Each FPV-Ab Rapid Quantitative Test includes an internal control for quality assurance. This internal control is conducted with each patient sample test. If an invalid result occurs, the meter will display an error message, indicating the need for a retest.

Interpretation of Results

Reference Range of FPV-Ab in Canine Serum or Plasma: Detection Range: 4.5–640 Tu/ml Reference Range: Item Result (Tu/ml) Level Suggestion ≤ 9 0 No antibody protection; vaccination recommended. 9 – 50 1 Weak antibody protection; supplementary immunization or adjusted immunization program advised. 50 – 150 2 Weak antibody protection; supplementary immunization or adjusted immunization program advised. 150 – 300 3 Moderate antibody protection; monitor antibody levels every 6 months. 300 – 500 4 Moderate antibody protection; monitor antibody levels every 6 months.

500 5 Strong antibody protection; annual testing recommended to ensure timely vaccine protection. Note: If the pet has not been vaccinated but shows a level above 1, it may indicate past infection. Each laboratory should establish a reference range appropriate to the population being tested.

Warnings and Limitations

For in vitro diagnostic use only. Inspect the packaging and labels before use; do not use if the pouch is damaged or the vial leaks. Do not use the test device beyond the expiration date. Use a new pipette tip for each specimen. Test results may be affected by technical or procedural errors, as well as unlisted substances in blood specimens.