Feline FPV/FHV/FCV Antibody Triple Test Kit
Catalog No.: MG-CA-R033
Quantitative feline FPV/FHV/FCV antibody combo — 3 viruses in 1 panel, 10–20 min results. ISO9001/GMP.
Indicative price range: US$20–80 per kit. Final pricing (specification, order quantity and OEM terms) is confirmed in the written quotation.
Catalog Number: MG-CA-R033
TL;DR — The Feline FPV/FHV/FCV Ab is a quantitative fluorescence immunoassay used with a Migibio Immunofluorescence Analyzer. It ships as a 2-year shelf life, an MOQ of 10, and a 10-minute Quick Test result. For clinical interpretation, see Feline Triple Test: FPV, Herpes and Calicivirus.
Applications & Who It’s For
- Veterinary clinics & animal hospitals — same-visit quantitative Feline FPV/FHV/FCV Ab results to support diagnosis and case management.
- Shelters & catteries — intake screening and vaccination or immunity screening where Feline FPV/FHV/FCV Ab is part of the admission panel.
- Breeders & kennels — monitor infection or immunity status in breeding and boarding groups.
- Reference labs & multi-vet hospitals — batch multiple devices on the analyzer for high-throughput reporting.
See also: Feline Triple Test: FPV, Herpes and Calicivirus.
Product Specifications
| Attribute | Value |
|---|---|
| Place of Origin | China |
| Classification | Specific Reagents |
| CAT No. | MG-CA-R033 |
| Package | Box |
| Appearance | liquid |
| Specification | 10T |
| Storage | Room Temperature |
| Shelf life | 2 years |
| MOQ | 10 |
| Suitable for | Veterinary |
| Grade | Reagent Grade |
Specification
Tests per Box : 10 Catalog Number : MG-CA-R033
Intended Use
The Feline FPV/FHV/FCV Ab test is a quantitative assay used with an Immunofluorescence Analyzer to measure antibodies for feline panleukopenia virus (FPV), feline herpesvirus (FHV), and feline calicivirus (FCV) in serum or plasma.
Clinical Significance
Feline panleukopenia (FPV), feline herpesvirus (FHV), and feline calicivirus (FCV) are the three core pathogens targeted by the standard feline vaccination protocol. Measuring antibody titres against all three simultaneously provides a convenient assessment of vaccination efficacy and immune status.
A single quantitative triple test helps clinicians determine whether a cat has protective immunity, identify animals requiring booster vaccination, and optimise vaccination schedules for multi-cat environments.
Test Principle
This test uses a double antigen sandwich fluorescence method. The intensity of the fluorescent signal indicates the concentration of antibodies, expressed as Tu/ml.
Materials
Provided: 10 sealed pouches with test devices for FPV-Ab, FHV-Ab, and FCV-Ab Desiccant pouch 1 ID Chip Instructions for Use 10 tubes of FPV/FHV/FCV Ab Sample Buffer 10 pipette tips Required But Not Provided: Immunofluorescence Analyzer Timer Pipette (already provided) Centrifuge (typically not needed)
Storage and Stability
Store at 4-30°C until the expiration date. Perform tests at 18-28°C after opening. Use the test within 30 minutes of opening the pouch.
Specimen Collection and Preparation
Use serum or plasma (EDTA recommended). Separate serum or plasma within 3 hours of collection. Use only clear, non-hemolyzed specimens. Store specimens at 2-8°C for up to 72 hours or below -20°C for long-term storage.
Test Procedure
Preparation: Place a Test Device on a flat surface. Insert the ID Chip into the meter and ensure the Test Device lot number matches. Sample Preparation: Mix 20 μl of sample with FPV/FHV/FCV Ab Sample Buffer. Run the Test: Standard Test : Pipette 100 μl of mixed sample into the test device. Select “Standard Test” on the meter, insert the device, and click “Start Test.” Repeat for each test device. Quick Test : Pipette 100 μl of mixed sample into the test device. Select “Quick Test,” start the timer, and let the device sit for 10 minutes. Insert it into the meter and click “Start Test.” Repeat for each test device.
Results
Results appear on the screen. Print results if needed.
Quality Control
The test includes an internal quality control. If it fails, an error message will appear, and you’ll need to use a new Test Device and sample.
Interpretation of Results
FPV-Ab : 4.5–640 Tu/ml FHV-Ab : 5.0–640 Tu/ml FCV-Ab : 5.0–640 Tu/ml Refer to the results table for interpretation based on antibody levels.
Warnings and Limitations
For in vitro diagnostic use only. Do not use if packaging is damaged. Use one pipette tip per specimen. Results may be affected by technical errors or substances in the blood not listed. Each lab should establish its own reference ranges.
Clinical Context
When to Test
After feline core vaccination or when immune status and booster need need to be assessed in an individual cat or a multi-cat group.
Why Test
Simultaneous measurement of FPV, FHV, and FCV antibodies can support assessment of core vaccination response and immune status.
Interpretation
Use the quantitative titres with the kit IFU, vaccination history, and exposure risk; each pathogen should be interpreted separately and in clinical context.
Limitations
Antibody titres do not by themselves prove complete protection and should not replace clinical judgement, vaccination history, or other diagnostics.
FAQ
What is the intended use of the Migi (Cat) Feline FPV/FHV/FCV Ab Rapid Quantitative Test Kit?
The Feline FPV/FHV/FCV Ab test is a quantitative assay used with an Immunofluorescence Analyzer to measure antibodies for feline panleukopenia virus (FPV), feline herpesvirus (FHV), and feline calicivirus (FCV) in serum or plasma.
What detection principle does the Migi (Cat) Feline FPV/FHV/FCV Ab Rapid Quantitative Test Kit use?
This test uses a double antigen sandwich fluorescence method. The intensity of the fluorescent signal indicates the concentration of antibodies, expressed as Tu/ml.
What are the storage and stability requirements?
Store at 4-30°C until the expiration date. Perform tests at 18-28°C after opening. Use the test within 30 minutes of opening the pouch.
How are the results interpreted?
FPV-Ab : 4.5–640 Tu/ml FHV-Ab : 5.0–640 Tu/ml FCV-Ab : 5.0–640 Tu/ml Refer to the results table for interpretation based on antibody levels.
Which analyzer does this run on?
It is used with a Migibio Immunofluorescence Analyzer; follow the analyzer operation manual.
What is the MOQ and shelf life?
The listed MOQ is 10; shelf life is 2 years.
What sample does it use?
Use serum or plasma (EDTA recommended).